Description

Product Features
1, True Realization on Online Double Conversion
2, Through High Performance Machine run by DSP Technology
3, Output Power Factor up to 0.8
4, Battery can adjust between16~20 Blocks
5, Charging Current can be adjusted from 0.5~6A by using
6, Single Phase Grid Power Input Range110~300VAC
7, Emergency Power Off (EPO)
8, ECO Mode have saving Energy effect
9, 3 Steps Extendable Charging Design,it can ensure the long use of the battery
10, 3 phase input include power factor correction function
11, N+X Parallel Redundancy

 

Application:
Widely used by Industry in Finance, Telecommunication, Government Sector, Transportation, Manufacturing,Education etc

 

Technical Parameters:

Model N.O. PMO-3310 PMO-3315 PMO-3320 PMO-3330
Phase 3 Phase in and out
Capacity 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW
Input Voltage 3x400VAC(3 Ph+N)
Voltage Range 190-520VAC(3 Ph) at 50% Load;305-478 VAC(3-Ph) at 100% Load.
Frequency Range 46-54Hz or 56-64Hz
Power Factor ≧0.99 @ 100% Load
Output Voltage 3 Phase 380VAC(3Ph+N)
Voltage Range(Batt.Model) ±1%
Frequency Range
(Synchronized Range)
46-54Hz or 56-64Hz
Frequency Range
(Batt.Mode)
50Hz±0.1Hz or 60Hz±0.1Hz
Current Crest Ratio 3:1(Max)
THD ≦2% tHD(Linear Load),≦5% THD(Non-Linear Load)
AC-DC Transfer Time 0
Bypass Transfer Time 0
Efficiency AC Mode 0.89
Battery Mode 86% 88% 87%
Standard Machine Battery Battery Model 12V/7Ah
Quantity 20
Standard Charger Time 9 hour can charger 90%
Max Charger Current 1A 2A
Charger Voltage 273 VDC±1%
Long Run Machine Battery Battery Model
Quantity 20 pcs (16-20 Optional)
Max Charger Current 4A
Charger Voltage 273 VDC±1%
Indicators: LCD or LED Panel Load Power, Battery Capacity, AC Mode, By-passs Mode, Fault
Alarm Battery Mode Sounding Every 4 Seconds
Underload Sounding Every 1 Seconds
Overload Sounding Every 0.5 Seconds
Fault Continuously Sounding
NW (kgs) 44 50.3 62.3
GW (kgs) 60 66.3 82
Unit Dimension(W*H*D) mm 558*250*820(with Wheel) 780*250*820
(with Wheel)
Wooden Case with Pallet Dimension
(W*H*D) mm
710*385*1108 932*385*1108
Environment Humidity 0-95% RH @ 0-45 ℃ (non-condensing)
Noise Level Less than 60dB @1 Meter Less than 65dB @1 Meter
Control Management RS-232/USB Suppor Windows 2000/2003/XP/Vista/2008,Windows7/8, Linux, Unix, and MAC
Optional SNMP Power Management from SNMP Manager and Web