Description
Product Description:
POMING’s PMUG-33 series of high-power three-phase input and output UPS has a single machine capacity ranging from 10KVA to 400KVA. This series of products adopts advanced DSP digital technology, combined with high-speed 16 bit digital chips, ASIC DDC control technology, and advanced high-power devices IGBT and SCR, to design intelligent UPS with large capacity, high reliability, and excellent performance. This series of products is the crystallization of the latest international hardware and advanced software, and can provide multiple parallel operations.
Application:
This series of products is widely used in communication centers, precision instruments CAD、CAM、 Hospitals, military facilities, CNC equipment, SMT equipment, IT industry, computers and peripheral equipment, multi line slicing machines, and large motors.
Outstanding Feautures:
1, Dual static switch
A dual circuit non-contact static switch consisting of 12 SCR (silicon controlled rectifiers) on the inverter side and bypass side ensures uninterrupted switching between inverter power supply and bypass power supply, and guarantees the continuity and smoothness of the output voltage waveform. The control circuit adopts the “zero crossing” switching technology, ensuring that the UPS has a synchronous phase-locked switching time of 0ms. When it is not synchronized with the power grid, the switching time is less than 4ms, which means that no matter how the power grid frequency changes, the output voltage and frequency of the UPS can be ensured to be stable and uninterrupted.
2, Self diagnosis and self-protection
The PMUG-33 series UPS has extremely strong self diagnostic function, with 32 sensor detection and monitoring points set up throughout the machine, coupled with DSP ultra high speed detection and response, making the self-protection function of the PMUG-33 series UPS very complete. With more than 200 fault information prompts, real-time information data recording, equipment parameter setting, processing and diagnostic functions, the UPS can enter the protection state in a timely manner. In addition, the machine is specially designed with an emergency shutdown system for equipment.
3, Intelligent management of charging and batteries
It can automatically adjust the high current charger of 1A-50A, battery self diagnosis and maintenance system, battery self selection maintenance mode, battery automatic alarm system, battery periodic charging and discharging cycle system, system no-load protection setting selection, etc.
4, Human computer dialogue, remote monitoring, and networked management
4.1, The PMUG-33 series UPS panel is equipped with a large screen ultra bright backlit LCD touch display screen and a 320 * 240 dot matrix full Chinese display mode, which is completely suitable for domestic users to use and operate.
4.2, The LCD display screen can display over 200 pieces of information in real-time and cyclically show the running status of the mains and UPS. The PMUG-33 series UPS panel has multiple function and parameter setting buttons, fully realizing the two-way dialogue of human-computer interaction. It can be said that the PMUG-33 series UPS is tailor-made for users.
4.3, Optional Winpower power power management software is available, and it is also compatible with various power management software from Megatec in Taiwan.
Through the RS-232 serial communication interface, UPS can communicate with load computers or other monitoring devices to achieve multifunctional and multi-purpose monitoring and management operations, and SNMP cards can be selected to form a network management system.
5, Powerful Chinese/English display interface
Adopting a fully digital touch screen large LCD display in both Chinese and English, the display content can be selected and set in Chinese/English, and the running status, operating procedures, data collection, fault maintenance information, and other contents are clear at a glance.
6, Dual transformation true online design
Adopting DSP full digital control technology, UPS control is precise, fast, reliable, stable, with complete protection functions and high reliability; The distortion of the output waveform is small.
7, Flexible parallel technology
Suitable for different loads and systems, it can operate as a single machine, 1+1 parallel machine, or multiple machines (N+1) parallel machine.
8, High system efficiency
Using ECO working mode, the efficiency is over 98%.
9, Output transformer
The isolation function of the output transformer reduces harmonic currents and interference from the mains to the load.
10, Featuring optional 12 pulse rectification
Improving the input power factor of UPS effectively suppresses the harmonic pollution caused by UPS to the power grid,
11, Allow 100% unbalanced work
Adopting three-phase independent modulation and full bridge inverter technology, it can provide normal and reliable power supply even when the three-phase load is 100% unbalanced.
12, Intelligent battery management function
An independent battery detection package can be selected, and parameters can be set through the operation interface according to the battery configuration capacity. The charging current can be automatically adjusted by the software, and the battery automatic detection and charging/discharging interval time can be set according to the safety situation of the power grid to extend the battery service life and truly achieve intelligent battery management.
13, Rich communication function interfaces
Powerful intelligent monitoring function, providing RS232, RS485 communication ports, built-in modem interface, battery detection interface, and multiple dry contact signal interfaces, truly realizing multi-purpose communication and remote monitoring.
14, Complete protection functions
Equipped with multiple system protection functions, it can detect and alarm abnormal conditions such as overvoltage, undervoltage, overcurrent, overload, and short circuit, and has strong environmental adaptability.
15, Sound and light alarm
Equipped with sound and light alarm function, it is conducive to remote visual management and eliminates unexpected losses caused by traditional UPS that cannot be monitored in real time. Green light: UPS is running normally; Yellow light: Running in battery mode; Red light: maintenance alarm.
16, Multi channel output
10~80KVA has 4 outputs, which can integrate various devices without the need for external switch boxes.
17, Multiple voltage outputs
Compatible with various input and output voltage specifications, the output adopts copper wire wound isolation transformer, with low loss and low heat generation, compatible with various voltages such as Japanese, American, and mainland China,
18, Color options
The host and battery box are coated with imported paint and can be customized according to user requirements, with the same color tone as the on-site equipment. Available colors: beige, computer white, cool gray.
Technical Parameters:
Model: PMUG-33 | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 150KVA | 200KVA | 300KVA | 400KVA | |
Nominal capacity(KVA) | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 150 | 200 | 300 | 400 | |
Maximum current for single phase input(A) | 19 | 29 | 38 | 57 | 76 | 114 | 152 | 189 | 227 | 303 | 379 | 568 | 609 | |
Work principle | On-line power supply, static bypass switch (uninterrupted switch) double conversion technology | |||||||||||||
AC input | Number of phase | Three-phase+N+G | ||||||||||||
Nominal voltage | 380VAC±25% | |||||||||||||
Nominal frequency | 50Hz±10%,60Hz±10% | |||||||||||||
Voltage harmonic distortion | <10% | |||||||||||||
Soft sart | 0-100% 5 sec | |||||||||||||
Bypass | Number of phase | Three-phase+N+G | ||||||||||||
Nominal voltage | 380VAC±15% | |||||||||||||
Nominal frequency | 50Hz/60Hz±10% | |||||||||||||
Inverter/bypass(switching time) | 0 ms | |||||||||||||
Battery | Number of battery unit | 30 No./12V in series | ||||||||||||
Nominal battery voltage | 360V | |||||||||||||
maximum discharge current(A) | 25 | 38 | 51 | 76 | 101 | 152 | 203 | 253 | 305 | 405 | 550 | 760 | 1015 | |
Float chargin voltage | 405V(battery automatically charging every 3 months,charging voltarge 435V) | |||||||||||||
Charging curret | 1A-50A (setting according to battery capacity) | |||||||||||||
inverter | Load power factor | 0.8 (0.9optinal) | ||||||||||||
Number of phase | Three-phase+N+G | |||||||||||||
Nominal voltage | 380VAC±1%(for steady-state load), 380VAC±3%(for the load which is fluctuated) | |||||||||||||
Nominal frequency | 50Hz±0.05%, 60Hz±0.05%(powered by the battery) | |||||||||||||
Frequency stability:when not in synchronization | <±0.05% | |||||||||||||
Frequency stability:when in synchronization | <±5% | |||||||||||||
Output waveform | Sine wave | |||||||||||||
Total harmonic distortion | Lindar load<2%:The nonlinear load<4% | |||||||||||||
Dynamic load voltage transient | <5% (from 0 to 100%) | |||||||||||||
Transient recovery time | <10ms (±5%) | |||||||||||||
Unbalanced voltage | <±1%(Balanced load voltage), <±3%(Unbalanced load voltage) | |||||||||||||
Overload capacity | Maintain for ten min then turn to the bypass for 125% overload, and 1 min for 150% overload. | |||||||||||||
The inverter efficiency and load by 100% | 0.95 | |||||||||||||
The system structure | Total efficiency of 100% load | 91%, 95%, ECO | ||||||||||||
Computer ommunication interface | RS232,(Rs485, Network remote monitoring software) | |||||||||||||
Operating temperature | 0-40ºC | |||||||||||||
Relating humidity | 0-90% without any condensation | |||||||||||||
Running high | <1500m(The power drops by 1% for every additional 100 meters, up to 4000 meters) | |||||||||||||
Cooling way | Forced ventination (temperature control) | |||||||||||||
Noise(db) | <65 | |||||||||||||
The body color | black | |||||||||||||
The input cable | The bottom/bcak | |||||||||||||
Easy to maintain | Front, top, left and right sides can be opened | |||||||||||||
Input device | Terminal block | |||||||||||||
Output device | Terminal block | |||||||||||||
Size (D×W×H) | 725×450×1135 | 855x450x1235 | 715x855x1500 | 1100x900x1700 | 1200x1500x1800 | 1300x1800x1800 | ||||||||
The host weight(kg) | 200 | 250 | 340 | 400 | 480 | 650 | 900 | 1200 | 1300 | 1480 | 2000 | 2100 | 2500 | |
Optional parts | RS485,parallel board,network management system,battery testing sydstem,lightning protection devices, pls specify when ording. |